Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
BMC Chem ; 17(1): 22, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36927568

RESUMO

Enantioseparation of five ß-adrenergic blockers was studied using two mobile phases on a cellulose tris(3-chloro-4-methylphenylcarbamate) (Lux-Cellulose-2) chiral column in normal phase mode. The first mobile phase composed of n-hexane: ethanol: diethylamine 60: 40: 0.1 by volume has successfully resolved the chromatographic peaks of three pairs of ß-adrenergic blockers namely, bisoprolol, carvedilol and atenolol. A mixture of n-hexane: ethanol: diethyl amine 75: 25: 0.1 by volume was used as the second mobile phase to separate the four pairs of enantiomers, metoprolol, carvedilol, nebivolol and atenolol with high resolution values. The mobile phases were pumped at a flow rate 1 mL/min with column temperature 25 °C using a UV detector at 230 nm. Molecular docking simulations of the five pairs of enantiomers was carried out in the cavities of the chiral stationary phase to gain a better understanding of the interaction between analyte enantiomers and chiral stationary phase and to better understand the mechanism of chiral recognition. According to the results, hydrogen bond interactions and π-π- interactions were the main types of interaction involved in the chiral recognition. Molecular dynamics simulation was performed to investigate the solvent effect on the interaction of the five pair of enantiomers in the chiral stationary phase cavity under dynamic conditions.

2.
J Chromatogr Sci ; 61(1): 74-86, 2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-34894146

RESUMO

An isocratic reversed-phase high performance liquid chromatographic method has been developed and validated to simultaneously determine nicotinic acid, pravastatin sodium, rosuvastatin calcium, atorvastatin calcium, pitavastatin calcium, lovastatin sodium and simvastatin sodium in focus on counterfeit drug detection. Thin-layer chromatography, nuclear magnetic resonance and mass spectrometry have been additionally performed to verify the identification of adulterants of counterfeit herbal medicines. Chromatographic separation was carried out on Inertsil® ODS-3 C18 (4.6 × 150 mm, 5 µm) with isocratic mobile phase elution containing a mixture of acetonitrile: methanol: 25 mM potassium dihydrogen phosphate buffer, pH 2.86 adjusted with 0.1 M o-phosphoric acid (48: 30: 22, v/v/v), at a flow rate of 1 mL/min and with UV detection at 238 nm. The design of experiment methodology, Plackett-Burman and Box-Behnken designs, was used to screen and optimize the mobile phase composition. The validation of the method was also carried out under the International Conference on Harmonization guidelines. The developed method was sensitive, accurate, simple, economical and highly robust, in addition to the comprehensiveness and novelty of this method for separating the seven drugs. The results were statistically compared with the reference methods used Student's t-test and variance ratio F-test at P < 0.05.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases , Niacina , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Preparações Farmacêuticas
3.
J AOAC Int ; 104(6): 1667-1680, 2021 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-34410406

RESUMO

BACKGROUND: Drug counterfeiting is a rising problem due to difficulties with identifying counterfeit drugs and the lack of regulations and legislation in developing countries. OBJECTIVE: This study aims to develop a robust and economic reversed phase high performance liquid chromatography (LC) method for simultaneously determining metformin HCl, vildagliptin, saxagliptin, alogliptin benzoate, sitagliptin phosphate monohydrate, and linagliptin to target counterfeiting. METHODS: Plackett-Burman (PB) and Box-Behnken (BB) designs were used to screen and optimize the mobile phase composition. Chromatographic separation was carried out on an Inertsil® ODS-3 C18 column with isocratic elution mode and the mobile phase was a mixture of acetonitrile-methanol-ammonium formate buffer, pH 3.5 (25:10:65, v/v/v). This method was applied to analyze synthetic drugs in three traditional Chinese and Indian herbal medicines. To identify the adulterants, thin-layer chromatography (TLC), nuclear magnetic resonance (NMR), and mass spectrometry (MS) were used on counterfeit herbal medicines. RESULTS: The developed method is sensitive, simple, rapid, economical, accurate, and highly robust. Student's t-test and variance ratio (F-test at P < 0.05) were used to compare the results statistically with the reference methods. CONCLUSION: The study found that the analyzed herbal medicines were adulterated with metformin and the quantification of anti-diabetic counterfeits was therefore applied. HIGHLIGHTS: This study determined counterfeited anti-diabetic drugs in Indian and Chinese traditional herbal medicines(THMs). Design-of-experiment, PB, and BB designs were used. Method validation was also performed in accordance with the International Conference on Harmonization guidelines.


Assuntos
Medicamentos Falsificados , Inibidores da Dipeptidil Peptidase IV , Metformina , Cromatografia Líquida de Alta Pressão , Humanos , Fosfato de Sitagliptina
4.
J Chromatogr Sci ; 59(8): 730-747, 2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-33367531

RESUMO

An isocratic reversed-phase high-performance liquid chromatographic method has been developed and validated for the simultaneous determination of aspirin, prasugrel HCl and clopidogrel bisulfate in the presence of clopidogrel-related compound (impurity-A) in focus on counterfeit. This method was used to determine counterfeited antiplatelet drugs in two substandard Indian pharmaceutical products sold on the market in Yemen and two traditional herbal medicines sold on the market in China. Thin layer chromatography and mass spectrometry of counterfeit herbal medicines have additionally been carried out to verify the identification of adulterants. Chromatographic separation was performed on Inertsil ® ODS-3 C18 (4.6 × 250 mm, 5 µm) with isocratic mobile phase elution containing a mixture of acetonitrile: (25 mM) potassium dihydrogen phosphate buffer, pH 2.7 adjusted with 0.1 M o-phosphoric acid (79: 21, v/v), at a flow rate of 1 mL/min and UV detection at 220 nm. Designs of experiment methodology, Plackett-Burman and Box-Behnken designs were used for the screening and optimization of the mobile phase composition. The method validation was also performed in accordance with the International Council on Harmonization (ICH) guidelines. The method developed for routine analysis was found to be sensitive, simple, accurate and highly robust. The results were statistically compared to reference methods using Student's t-test and variance ratio F-test at P < 0.05.


Assuntos
Aspirina , Preparações Farmacêuticas , Cromatografia Líquida de Alta Pressão , Clopidogrel , Humanos , Cloridrato de Prasugrel
5.
Braz. J. Pharm. Sci. (Online) ; 55: e18084, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039041

RESUMO

Lycopene was reported to influence some cytochrome P450 enzymes activity. The present study investigates the effect of lycopene on the pharmacokinetics of paracetamol and chlorzoxazone. Lycopene (20 mg/kg) was intra-peritoneally administered to two groups of rats for eight consecutive days and two other groups were given vehicle. On the eighth day, chlorzoxazone and paracetamol were separately intravenously administered to a lycopene group and a control group. Blood samples were collected at different time intervals, treated and analyzed using HPLC. The HPLC method used for paracetamol analysis was based on isocratic elution using a mobile phase consisting of water: methanol, (77:23 v/v) at a flow rate 1 mL min−1, Kromasil C18 column, and UV detection at 254 nm using caffeine as internal standard. About chlorzoxazone, separation was carried out using water: acetonitrile (60: 40, v/v) as the mobile phase at a flow rate 1 mL min−1, Inertsil ODS-3 C18 column, UV detection at 283 nm and esomeprazole as internal standard. Statistical analysis of the pharmacokinetic data using student t test showed a significant increase in AUC 0-t , AUC 0-Inf and t1/2 of paracetamol (P<0.05) and of chlorzoxazone (P<0.05) in the groups pretreated with lycopene (20 mg/kg), significant increase in the volume of distribution of paracetamol (P < 0.05), but no significant difference in that of chlorzoxazone. In other words, paracetamol and chlorzoxazone showed significant decrease (P < 0.05), respectively. These results demonstrate that treatment of rats with Lycopene (20mg/kg, ip) has a significant effect on the metabolic clearance and the pharmacokinetics of both drugs


Assuntos
Animais , Masculino , Ratos , Clorzoxazona/farmacocinética , Licopeno/química , Acetaminofen/farmacocinética , Taxa de Depuração Metabólica/efeitos dos fármacos , Cromatografia Líquida de Alta Pressão/métodos , Área Sob a Curva
6.
Pak J Pharm Sci ; 28(6): 2041-51, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26639498

RESUMO

Two new hydrolytic products of letrozole were identified and proved to be true degradation products obtained by alkaline and acidic degradation of the drug. The acid and amide forms of the nitrile groups of letrozole were prepared and identified by IR and mass spectroscopic techniques. Subsequently, a simple, precise and selective stability-indicating RPLC method was developed and validated for the determination of letrozole in the presence of its degradation products. Letrozole was subjected to alkali and acid hydrolysis, oxidation, thermal degradation and photo-degradation. The degradation products were well isolated from letrozole. The chromatographic method was achieved using gradient elution of the drug and its degradation products on a reversed phase Zorbax Eclipse C18 column (100mm x 4.6mm, 3.5 µm) using a mobile phase consisting of 0.01M KH2PO4and methanol at a flow rate of 1 mL min⁻¹. Quantitation was achieved with UV detection at 230 nm. Linearity, accuracy and precision were found to be acceptable over the concentration range of 0.01-80 µgmL⁻¹. The proposed method was successfully applied to the determination of letrozole in bulk, plasma and in its pharmaceutical preparation.


Assuntos
Inibidores da Aromatase/química , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Contaminação de Medicamentos , Nitrilas/química , Tecnologia Farmacêutica/métodos , Triazóis/química , Inibidores da Aromatase/sangue , Calibragem , Química Farmacêutica , Cromatografia Líquida de Alta Pressão/normas , Cromatografia de Fase Reversa/normas , Estabilidade de Medicamentos , Temperatura Alta , Humanos , Concentração de Íons de Hidrogênio , Hidrólise , Letrozol , Modelos Lineares , Espectrometria de Massas , Nitrilas/sangue , Oxirredução , Fotólise , Padrões de Referência , Reprodutibilidade dos Testes , Tecnologia Farmacêutica/normas , Triazóis/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...